高级检索
    张小涛, 侯宏卫, 陈欢, 刘勇, 王安, 胡清源. 液相色谱串联质谱法测定卷烟主流烟气中的苯并[a]芘[J]. 中国烟草科学, 2016, 37(6): 77-81. DOI: 10.13496/j.issn.1007-5119.2016.06.014
    引用本文: 张小涛, 侯宏卫, 陈欢, 刘勇, 王安, 胡清源. 液相色谱串联质谱法测定卷烟主流烟气中的苯并[a]芘[J]. 中国烟草科学, 2016, 37(6): 77-81. DOI: 10.13496/j.issn.1007-5119.2016.06.014
    ZHANG Xiaotao, HOU Hongwei, CHEN Huan, LIU Yong, WANG An, HU Qingyuan. Determination of Benzo[a]pyrene in Mainstream Cigarette Smoke by Liquid Chromatography Tandem Mass Spectrometry[J]. CHINESE TOBACCO SCIENCE, 2016, 37(6): 77-81. DOI: 10.13496/j.issn.1007-5119.2016.06.014
    Citation: ZHANG Xiaotao, HOU Hongwei, CHEN Huan, LIU Yong, WANG An, HU Qingyuan. Determination of Benzo[a]pyrene in Mainstream Cigarette Smoke by Liquid Chromatography Tandem Mass Spectrometry[J]. CHINESE TOBACCO SCIENCE, 2016, 37(6): 77-81. DOI: 10.13496/j.issn.1007-5119.2016.06.014

    液相色谱串联质谱法测定卷烟主流烟气中的苯并a芘

    Determination of Benzoapyrene in Mainstream Cigarette Smoke by Liquid Chromatography Tandem Mass Spectrometry

    • 摘要: 为准确、快速地测定卷烟主流烟气中苯并a芘的含量,建立了液相色谱-大气压光电离-串联质谱测定卷烟主流烟气中苯并a芘的方法。方法对助剂流速、萃取溶剂、烟支数和色谱质谱测定的条件进行了优化,结果表明,当甲苯流速为80 µL/min,环己烷作为萃取溶剂,Agilent PAH(100 mm×2.1 mm,3.5 µm)作为色谱柱,95%的乙腈和5%的水为流动相,色谱柱温度为40℃,方法检出限为0.15 ng/mL,苯并a芘回收率100%~107%,相对标准偏差小于10%,分析时间为6 min,与现行的GC-MS测定卷烟主流烟气中苯并a芘的国家标准方法相比大大缩短了分析时间。该方法具有灵敏度高、分析时间短等优点,可以显著地提高分析的通量。

       

      Abstract: In order to accurately and rapidly determine BaP content in mainstream cigarette smoke, a liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (LC-APPI-MS/MS) for determination BaP in mainstream cigarette smoke was developed and validated. The flow rate of toluene, extraction solvent, number of cigarette and the conditions of liquid chromatography and mass spectrometry were optimized. The results indicated that when the flow rate of toluene was 80 µL/min, cyclohexane was used as extraction solvent, chromatographic separation was achieved by using an Agilent PAH column (100 mm×2.1 mm, 3.5 μm) at 40℃, and 95% acetonitrile and 5% water was selected as the mobile phase, the detection limit of the method was 0.15 ng/mL, the recovery of BaP was 100%-107%, the relative standard deviation was less than 10%, and the analysis time was 6 min. Compared with the existing GC-MS method for the determination of BaP in mainstream cigarette smoke, this method shortened the analysis time. The proposed method has the advantages of high sensitivity and short analysis time etc., which can significantly improve the throughput.

       

    /

    返回文章
    返回